Skip to content
Nextriv

Sense environmental sensors

Nextriv Sense IndustrialIP67 temperature and humidity sensor

SKU: NX-SN-IND

Versatile temperature and humidity sensor in an IP67 enclosure — for indoor and outdoor use. EN12830 certified for the cold chain.

€87net

VAT is added to the price.

Nextriv Sense Industrial — product photo
Nextriv Sense Industrial — view 2
Nextriv Sense Industrial — view 3
Nextriv Sense Industrial — view 4
Nextriv Sense Industrial — view 5
Nextriv Sense Industrial — view 6
Nextriv Sense Industrial — view 7
Nextriv Sense Industrial — view 8
Nextriv Sense Industrial — view 9
Nextriv Sense Industrial — view 10
Nextriv Sense Industrial — view 11
Nextriv Sense Industrial — view 12
Image 1 of 12

Description

  • One device for indoors and outdoors
  • EN12830 certified for the cold chain
  • Tamper-proof measurement log for audits
  • NFC setup without opening the enclosure
  • Years of battery life, zero cabling

What it is for

Nextriv Sense Industrial at an angle — rugged housing for harsh environments

Nextriv Sense Industrial was born of a simple observation: most temperature and humidity sensors split the world into "indoors" and "outdoors" — and buildings don't respect that split. A warehouse worker needs measurements in the hall and on the loading dock, a grower in the greenhouse and in the field, an administrator in the server room and in the utility pit. So this sensor got a sealed IP67 enclosure made of flame-retardant, UV-resistant plastic: one device, one setup procedure, any mounting location — from an office wall to a post outside the building.

The second pillar is data credibility, not just data collection. Sense Industrial keeps a local log of nearly 2800 measurements that cannot be manually wiped — a deliberate design decision for audits and disputes: the reading history is inviolable. If connectivity disappears for a while, the sensor keeps measuring and forwards the backlog on its own once the network returns. In practice that means a chart with no gaps — exactly what a sanitary inspector, a pharmaceutical auditor or an insurer demands. EN12830 certification for cold-chain temperature recorders closes the formal side of the matter.

The third pillar is zero maintenance. Configuration and power-on happen contactlessly over NFC from the mobile app — the enclosure never needs to be opened, so the seal stays intact, and commissioning dozens of units is a matter of tapping a phone against each one. The battery lasts for years, the enclosure has a second slot for an optional extra battery, and mounting is a choice: screws, double-sided 3M tape or cable ties.

±0.3 °C accuracy means an alarm set at 8 °C in a pharmacy fridge really does watch 8 °C, while 0.1 °C resolution reveals trends — a slowly drifting cold room is visible long before the threshold is crossed. Radio range of up to approx. 2 km in built-up areas and approx. 15 km in open terrain lets a single gateway cover an entire plant or farm.

Usage scenarios

  • Pharmacy chain: one sensor in the medicine fridge and another on the sales floor. During a pharmaceutical inspection the manager exports a continuous, uneditable temperature history — including the night the internet went down, because the sensor backfilled the data from its local buffer.
  • Class A office building: dozens of sensors across the floors feed the HVAC automation with real conditions in the zones, not just at the air intakes. The facility manager gets a threshold alarm before tenants start calling that "it's stuffy".
  • Food warehouse: measurement points in the dry zone, at the gates and on the outdoor dock — the same model everywhere, because the enclosure shrugs off both frost and driving rain. The storage-conditions report generates itself, ready for HACCP.
  • Horticultural greenhouse: sensors strapped to the structure every few dozen metres report the microclimate to a gateway kilometres away. The owner correlates humidity with ventilation settings instead of walking around with a thermometer.
  • Server room and utility spaces: one sensor on 3M tape by the rack and another in the switchboard room. A temperature threshold breach on the weekend is an instant notification, not a Monday surprise.
  • Museum and archive: stable conditions for collections documented in a log that cannot be "corrected" — an argument in conversations with the conservator and the insurer.

Key features

Back of the Nextriv Sense Industrial with ears for screw or strap mounting

  • One device for indoors and outdoors: an IP67 enclosure in flame-retardant ABS+PC, resistant to UV radiation.
  • Tamper-proof local log of approx. 2800 measurements — full data auditability.
  • Automatic retransmission: after a connectivity outage the sensor forwards the missed readings itself — gap-free history.
  • EN12830 certification — formal approval to act as a temperature recorder in the cold chain.
  • Configuration and power on/off contactlessly via NFC from a phone — no opening the enclosure, no cables.
  • Second battery slot as standard: an optional second battery significantly extends runtime.
  • Three mounting options in the box: screws, 3M tape, cable ties — from a wall to a pipe or mesh.
  • Direct triggering of other devices in the Nextriv network (no server involved) — e.g. the sensor switches on a fan by itself.
  • Operation across the full -30…70 °C range and 0–100 % humidity — from a freezer room to a boiler room.

In the Nextriv system

±0.3 °C accuracy only pays off with proper threshold handling — and here the Nextriv platform provides four thresholds per metric: two warning and two critical, so the 8 °C alarm in a pharmacy fridge can be preceded by a warning at 7 °C. Notifications go out over six channels (e-mail, SMS, web push, Discord, MS Teams, in-app sound), and escalation policies pass an unacknowledged alarm onward. The platform watches the sensor itself, too: no transmission for twice the reporting interval means an offline status and a notification.

For audits there are PDF reports — including variants with statistics, threshold-compliance sections and a cryptographic signature (SHA-256 with a QR code for verification) — plus calibration reminders with room for certificates. Measurement history reaches back up to 5 years. XLSX and CSV exports feed HACCP records, and virtual sensors average the readings of several points into a single zone-wide metric.

Typical deployments

  • Pharma: EN12830-compliant temperature recording — a full, uneditable measurement history at audit time, even after connectivity outages.
  • Cold storage and logistics: chambers, warehouses and docks under one watch — the same model indoors and out.
  • Agriculture and greenhouses: crop microclimate reported to a gateway even a dozen-plus kilometres away in open terrain.
  • Server rooms: a sensor by the rack and in the switchboard room — a threshold alarm instead of a Monday surprise.

Specification

Technical specificationNextriv Sense Industrial
Temperature-30…70 °C, ±0.3 °C (0…70 °C), ±0.6 °C (-30…0 °C), 0.1 °C resolution
Humidity0…100 % RH, ±3 % (10–90 % RH at 25 °C), ±5 % outside that range
Ingress protectionIP67, UV-resistant enclosure — indoor and outdoor mounting
CertificationEN12830 (temperature recorders for the cold chain)
ConnectivityLong-range radio, -137 dBm sensitivity
Radio rangeup to approx. 2 km urban, up to approx. 15 km in open terrain
Power1× replaceable Li-SOCl₂ battery 4000 mAh (optionally 8000 mAh)
Battery lifefrom approx. 5.8 years to over 10 years (EU868, depending on radio configuration; 10-min interval, 25 °C)
Local bufferapprox. 2800 records + retransmission after a connectivity outage
Dimensions and weightapprox. 88 × 85 × 27 mm, approx. 96 g
Operating conditions-30…70 °C, 0–100 % RH (non-condensing)
Mountingscrews, 3M tape or cable ties

Files

  • Nextriv Sense Industrial — datasheet

    pdf

    EN0.6 MBversion 1.0

    Download

All files in the download center

Not sure which set to choose?

Tell us about your facility and we'll match sensors and a gateway to the exact rooms you need to monitor — no unnecessary hardware.